Lycoming TEO-540-C1A Maintenance Manual page 534

Table of Contents

Advertisement

Fault ID
381
Fault
Description
Root Cause
Fault ID
382
Fault
Description
Root Cause
Fault ID
383
Fault
Description
Root Cause
Fault ID
384
Fault
Boot mode CAN error
Description
Root Cause
This fault indicates a CAN error occurred while in boot mode
Fault ID
385
Fault
Boot mode service tool timeout
Description
Root Cause
This fault indicates a loss of communication with service tool while in boot mode
Fault ID
386
Fault
Boot mode programming error
Description
This fault indicates a failure to program the unit potentially due to flash memory
Root Cause
corruption
1. With Ignition switch in OFF position, remove ECU power by pulling the ECU circuit breaker. Wait 10s
before resetting. Is fault active? If no, go to step 2. If yes, replace the ECU.
2. Clear Service faults using the FST by following the steps outlined in the "Access the Field Service
Tool" section in Appendix C or the latest revision of SSP-118.
Appendix D
Page 504
Fault Group
48
Troubleshooting Steps
Fault Group
48
Troubleshooting Steps
Fault Group
48
Troubleshooting Steps
Fault Group
49
Fault Group
49
Fault Group
49
Troubleshooting Steps for Faults 384 thru 386
TEO-540-C1A Engine Maintenance Manual
Fault Name
-Reserved-
Fault Lamp
Fault Name
-Reserved-
Fault Lamp
Fault Name
-Reserved-
Fault Lamp
Fault Name
[FAULT: BOOT CAN ERROR]
Fault Lamp
[FAULT: BOOT COMMS
Fault Name
TIMEOUT]
Fault Lamp
Fault Name
[FAULT: BOOT PROG ERROR]
Fault Lamp
© 2018 Avco Corporation. All Rights Reserved
None
None
None
None
None
None
November 2018