Lycoming TEO-540-C1A Maintenance Manual page 511

Table of Contents

Advertisement

TEO-540-C1A Engine Maintenance Manual
Fault ID
297
Fault
Manifold Temperature crosscheck fault
Description
This fault indicates the combined and inferred manifold temperature differ by more than a
Root Cause
calibrated maximum threshold. The fault will become inactive if the combined and
inferred values converge
1. Are there any active MAT sensor slew rate, circuit or range faults? If yes, refer to troubleshooting
section for the active fault. If no, go to step 2.
2. Contact Lycoming Engines.
Fault ID
298
Fault
Deck Temperature crosscheck fault
Description
This fault indicates the combined and inferred deck temperature differ by more than a
Root Cause
calibrated maximum threshold. The fault will become inactive if the combined and
inferred values converge
1. Are there any active deck temperature sensor slew rate, circuit or range faults? If yes, refer to
troubleshooting section for the active fault. If no, go to step 2.
2. Contact Lycoming Engines.
Fault ID
299
Fault
Manifold Pressure crosscheck fault
Description
This fault indicates the combined and inferred manifold pressure from throttle position
Root Cause
differ by more than a calibrated maximum threshold. The fault will become inactive if the
combined and inferred values converge
1. Are there any active MAP sensor slew rate, circuit or range faults? If yes, refer to troubleshooting
section for the active fault. If no, go to step 2.
2. Contact Lycoming Engines.
Fault ID
300
Fault
Air mass flow crosscheck fault
Description
This fault indicates the primary and secondary air mass flow differ by more than a
Root Cause
calibrated maximum threshold. The fault will become inactive if the primary and
secondary air mass flow rates converge
1. Are there any active venturi, CIP, or MAP sensor slew rate, circuit or range faults? If yes, refer to
troubleshooting section for the active fault. If no, go to step 2.
2. Contact Lycoming Engines.
© 2018 Avco Corporation. All Rights Reserved
November 2018
Fault Group
38
Troubleshooting Steps
Fault Group
38
Troubleshooting Steps
Fault Group
38
Troubleshooting Steps
Fault Group
38
Troubleshooting Steps
[FAULT: manifold temperature
Fault Name
cross-check]
Fault Lamp
[FAULT: deck temperature cross-
Fault Name
check]
Fault Lamp
[FAULT: manifold pressure cross-
Fault Name
check]
Fault Lamp
FAULT: air mass flow rate cross-
[
Fault Name
check]
Fault Lamp
FFL
FFL
FFL
FFL
Appendix D
Page 481

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents