Lycoming TEO-540-C1A Maintenance Manual page 558

Table of Contents

Advertisement

Fault ID
479
Fault
Description
Root Cause
Fault ID
480
Fault
Arithmetic processing unit fault
Description
This fault indicates a fault with the arithmetic processor possibly due to a memory
Root Cause
corruption or processor failure
Fault ID
481
Fault
Configurable value range check failed
Description
fault
This fault indicates one or more of the configurable values exceed their upper or lower
Root Cause
limits
Fault ID
482
Fault
Excessive programming time fault
Description
Root Cause
This fault indicates programming did not complete within the timeout limit
1. With Ignition switch in OFF position, remove ECU power by pulling the ECU circuit breaker. Wait 10s
before resetting. Is fault still active? If yes, replace ECU. If no, go to step 2.
2. Clear Service faults using the FST by following the steps outlined in the "Access the Field Service
Tool" section in Appendix C or the latest revision of SSP-118.
Fault ID
483
Fault
Description
Root Cause
Fault ID
484
Fault
Description
Root Cause
Appendix D
Page 528
Fault Group
60
Troubleshooting Steps
Fault Group
61
Fault Group
61
Fault Group
61
Troubleshooting Steps for Faults 480 thru 482
Fault Group
61
Troubleshooting Steps
Fault Group
61
Troubleshooting Steps
TEO-540-C1A Engine Maintenance Manual
Fault Name
-Reserved-
Fault Lamp
Fault Name
[FAULT: ArithPU]
Fault Lamp
[FAULT: configurable value range
Fault Name
check failed]
Fault Lamp
[FAULT: Excessive Programming
Fault Name
Time]
Fault Lamp
Fault Name
-Reserved-
Fault Lamp
Fault Name
-Reserved-
Fault Lamp
© 2018 Avco Corporation. All Rights Reserved
None
None
None
None
None
None
November 2018

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents