4. PERIODICAL MAINTENANCE PROCEDURE
[1]
[2]
38
A0P0F2C528DA
[2]
[1]
[3]
[4]
A0P0F2C527DA
Service Manual
Field Service Ver. 2.0 Jul. 2009
8. Remove the protective sheet [1] for
the PC drum.
9. Secure the drum unit/K [1] to the
developing unit/K with the two levers
[2].
NOTE
• Push the front and back levers in
the direction of the arrow at a time
to secure the drum unit/K.
• Make sure the drum unit/K is
securely fixed with two levers.
• Check that the front lever [3] of the
drum unit/K is parallel to the verti-
cal line marked on the label [4] on
the developing unit/K.
Y110571-1