Field Service Ver. 2.0 Jul. 2009
19.5.165 C8302: Cooling fan failure
Cooling fan (FM1)
Step
1
Check the connector of FM1 for proper
connection and correct as necessary.
2
Check the fan for possible overload and
correct as necessary.
3
FM1 operation check
4
Change FM1
5
DFCB F7 conduction check
6
Change DFCB
19.5.166 C8401: EEPROM failure
DF control board (DFCB)
Step
1
Disconnect and then connect the power
cord. Turn OFF the main power switch, wait
for 10 sec. or more, and turn ON the main
power switch.
2
Rewrite the firmware.
3
Change DFCB
Y110571-1