Field Service Ver. 2.0 Jul. 2009
19.5.19
C1109: Side-staple stapler motor drive malfunction
2 staples stapler motor (M14)
Stapler unit
Step
Check the motor and sensor connectors for
1
proper connection, and correct as neces-
sary.
Check the connector of M14 for proper
2
drive coupling, and correct as necessary.
3
Change stapler unit
4
M14 operation check
5
Change M14
6
FSCB ICP10 conduction check
7
FSCB ICP11 conduction check
8
Change FSCB
19.5.20
C1110: Center-staple head roller motor malfunction
Staple motor (M24)
Stapler home sensor (PS33)
Step
Check the motor and sensor connectors for
1
proper connection, and correct as neces-
sary.
Check the connector of M24 for proper
2
drive coupling, and correct as necessary.
3
PS33 I/O check, sensor check
4
M24 operation check
5
Change M24
6
SDDB ICP7 conduction check
7
Change SDDB
8
Change FSCB
Y110571-1
Relevant parts
Action
Relevant parts
Action
Service Manual
FS control board (FSCB)
WIRING DIAGRAM
Control signal
—
—
—
—
—
—
—
—
SD drive board (SDDB)
FS control board (FSCB)
WIRING DIAGRAM
Control signal
—
—
SDDB CN403-17 (ON)
SDDB CN406<B>-1 to 2
—
—
—
—
19. TROUBLE CODE
Location (Electri-
cal component)
—
—
—
—
—
—
—
—
Location (Electri-
cal component)
—
—
SD-508 C-10
SD-508 K-9 to
10
—
—
—
—
767