Field Service Ver. 2.0 Jul. 2009
12.9.14
Split Line Detect. Setting-Warning Level
A. Use
• To set how to display the warning when stain on the ADF original glass is detected.
• Use when changing the display of the warning which requests the cleaning of the stain
on the glass detected by the pre-detection of the lines.
0: Warning will not be displayed.
1: Warning will be displayed by the maintenance mark. (warning code: D-1/D-2)
2: Warning will be displayed on the message area on the basic screen.
3: Warning will be displayed on all screens.
NOTE
• This setting is invalid when [Prior Detection] is set to "Not Set."
B. Procedure
• The default setting is 2.
0
12.9.15
Split Line Detect. Setting-Paper Passaging Detection
A. Use
• To set the operation for detection and removing operation of stain on the ADF original
glass when feeding the original.
• Use when changing the operation for detection and removing operation of stain on the
ADF original glass when feeding the original.
0
: The glass will stop moving when the original is fed, and will not perform
removing the stain.
1
: The glass will move between originals when feeding the original.
B. Procedure
• The default setting is 1
12.9.16
Stamp
A. Use
• To set the mounting status of the optional stamp unit SP-501.
• To use when setting up the stamp unit SP-501.
B. Procedure
• The default setting is Unset.
Y110571-1
1
0
Set
Service Manual
12. SERVICE MODE
"2"
"1"
"Unset"
3
539