5.5.81
K PC drum motor (M18)
1. Take out the reinforcing plate.
See the steps 1 to 11 of high voltage unit/1 removing procedure.
See P.144
2. Open the upper right door.
[2]
[4]
[5]
[1]
7. To reinstall, reverse the order of removal.
Y110571-1
[1]
A0P0F2C168DA
[2]
[3]
[1]
A0P0F2C173DA
[3]
[2]
A0P0F2C174DA
Service Manual
5. OTHER MAINTENANCE ITEMS
3. Remove the screw [1], and remove
the rear right cover/3 [2].
4. Disconnect the connector [3], and
remove the harness from two wire
saddles [1] and the edge cover [2].
5. Remove the screw [4], and remove
the fan motor assy /2 [5].
6. Remove four screws [1] and the con-
nector [2], and remove the K PC
drum motor [3].
175