Field Service Ver. 2.0 Jul. 2009
8.2

Installing the original size detection 2 sensor (PS205)

8.2.1

Procedure

1. Remove the original glass.
See P.89
[2]
Y110571-1
8. COMMERCIALLY AVAILABLE PARTS
2. Remove the harness from two wire
[1]
[1]
A0P0F2E586DA
3. Connect the connector [1] of the
[3]
4. Using the screw [2], mount the origi-
[1]
A0P0F2E587DA
5. Select [Service Mode]
A00JF2E587DA
Service Manual
saddles [1].
original size detection 2 sensor.
nal size detection 2 sensor [3] and fix
it.
[Original Size Detection], and set
the original glass to [Table2].
[System 1]
251