4. PERIODICAL MAINTENANCE PROCEDURE
4.11 Vertical conveyance section
4.11.1
Cleaning of the paper dust remover
A. Periodically cleaning parts/cycle
• Paper dust remover: Every 100,000 counts
B. Procedure
1. Open the upper right door.
[1]
[2]
70
2. Pushing the hook [1], remove the
paper dust remover [2].
A0P0F2C001DA
3. Using a brush, whisk dust off the
[1]
paper dust remover [1].
A0P0F2C002DA