19. TROUBLE CODE
19.5.130 C392A: Fusing sensor contamination (NC sensor)
Fusing unit
Heating roller temperature sensor/1 (TEMS1)
Step
1
Wipe the TEMS1 clean of dirt if any.
<Cleaning procedure>
• Clear away a dirt or a foreign object on
the sensor with a cotton swab.
• When a dirt is left even if you cleaned the
sensor by above procedure, clear away a
dirt or a foreign object on the sensor
using a cotton swab dampened with the
alcohol.
And, wipe off the sensor with a dry cot-
ton swab afterwards.
2
Check the TEMS1 for installed position and
proper connector connection.
3
Check the connection of the fusing unit.
4
Check the fusing unit, IHPU, PRCB and
DCPU for proper connection and correct or
change as necessary.
5
Change TEMS1
6
Change fusing unit
7
PRCB ICP17 conduction check
8
Change PRCB
812
Relevant parts
Action
Service Manual
Field Service Ver. 2.0 Jul. 2009
IH power supply (IHPU)
DC power supply (DCPU)
Printer control board (PRCB)
WIRING DIAGRAM
Control signal
—
—
—
—
—
—
—
—
Location (Electri-
cal component)
—
—
—
—
—
—
—
—
Y110571-1