Field Service Ver. 2.0 Jul. 2009
19.5.161 C8102: Turn around pressure welding alienation trouble
Switchback roller pressure/retraction motor (M5)
Reverse roller sensor (PS7)
Step
1
Check the motor and sensor connectors for
proper connection, and correct as neces-
sary.
2
Check the connector of M5 for proper drive
coupling, and correct as necessary.
3
PS7 I/O check, sensor check
4
DFCB F9 conduction check
5
M5 operation check
6
Change M5
7
DFCB PS2 conduction check
8
Change DFCB
19.5.162 C8103: Lift up mechanism trouble (Upward movement)
Lift-up motor (M6)
Lift-up upper sensor (PS16)
Step
1
Check the motor and sensor connectors for
proper connection, and correct as neces-
sary.
2
Check the connector of M6 for proper drive
coupling, and correct as necessary.
3
PS16 I/O check, sensor check
4
M6 operation check
5
Change M6
6
Change DFCB
Y110571-1
Relevant parts
Action
Relevant parts
Action
Service Manual
DF control board (DFCB)
WIRING DIAGRAM
Control signal
—
—
REYB PJ3-3 (ON)
—
DFCB PJ6-10 to 11
—
—
—
DF control board (DFCB)
WIRING DIAGRAM
Control signal
—
—
DFCB PJ11-3 (ON)
DFCB PJ5-6 to 7
—
—
19. TROUBLE CODE
Location (Electri-
cal component)
—
—
DF-618
K to L-10
—
DF-618 I-7
—
—
—
Location (Electri-
cal component)
—
—
DF-618 B-6
DF-618 I-7 to 8
—
—