C2558: Abnormally High Toner Density Detected Black Tcr Sensor - Olivetti d-Color MF651 Service Manual

Color printer
Hide thumbs Also See for d-Color MF651:
Table of Contents

Advertisement

Field Service Ver. 2.0 Jul. 2009
19.5.91

C2558: Abnormally high toner density detected black TCR sensor

Drum unit /K
Toner cartridge /K
Step
1
Reinstall drum unit/K
2
Reinstall toner cartridge
3
Change drum unit/K
4
PRCB ICP17 conduction check
5
Change PRCB
6
Change sub hopper unit
19.5.92
C2559: Cyan TCR sensor adjustment failure
19.5.93
C255A: Magenta TCR sensor adjustment failure
19.5.94
C255B: Yellow TCR sensor adjustment failure
Imaging unit /C
Imaging unit /M
Imaging unit /Y
Step
1
Reinstall imaging unit
2
Change imaging unit
3
PRCB ICP1 or ICP2 conduction check
4
PRCB ICP17 conduction check
5
Change PRCB
19.5.95
C255C: Black TCR sensor adjustment failure
Drum unit /K
Step
1
Reinstall drum unit /K
2
Change drum unit /K
3
PRCB ICP17 conduction check
4
Change PRCB
Y110571-1
Relevant parts
Action
Relevant parts
Action
Relevant parts
Action
Service Manual
Sub hopper unit
Printer control board (PRCB)
WIRING DIAGRAM
Control signal
Printer control board (PRCB)
WIRING DIAGRAM
Control signal
Printer control board (PRCB)
WIRING DIAGRAM
Control signal
19. TROUBLE CODE
Location (Electri-
cal component)
Location (Electri-
cal component)
Location (Electri-
cal component)
801

Advertisement

Table of Contents
loading

This manual is also suitable for:

D-color mf551D-color mf451

Table of Contents