Split Line Counter - Olivetti d-Color MF651 Service Manual

Color printer
Hide thumbs Also See for d-Color MF651:
Table of Contents

Advertisement

Field Service Ver. 2.0 Jul. 2009

12.10.13 Split Line Counter

A. Use
• To display the average number of detected stain on the ADF original glass at the pre-
detection.
• Used for checking the number of detected stain on the ADF original glass.
Pre-detect Large Size
Pre-detect Small Size
Detect Split line in acting : Number of detected stain on the original glass during the
B. Procedure
• To clear each counter value, select the items to be cleared, and press the Clear key.
(When selecting [Pre-detect Large Size] or [Pre-detect Small Size] is selected, both val-
ues will be cleared.)
• If the count is cleared mistakenly, press the Interrupt key, which will undo the clearing
operation.
12.10.14 Parts Counter (Fixed)
• It will be displayed only when the optional finisher is mounted.
A. Use
• When the optional finisher is mounted, the parts counter screen displays the relevant
parts and their counts. When the relevant parts are replaced, their counters need to be
reset to update the service history.
• When the optional finisher is mounted, the relevant parts counter can be checked from
this menu.
• Service history can be maintained from this menu.
NOTE
• See the table below for the relevant parts and count method.
B. Procedure
1. Touch in the order of [Service Mode]
2. Check the parts counter or display the relevant part of which counter will be reset.
3. Check the part count.
To reset the count value, touch the key of the part where the counter is reset. Touch the
Clear key.
(1) Fixed parts to be counted
CSRC
No.
Parts name
param-
eter
001
43
FNS 2-Staple Stapler AVGR10781X
002
44
FNS Center Staple &
Fold Stapler
Y110571-1
: Large-sized detected stain divided by the number of times
pre-detection is practiced (average number of detected
lines) will be displayed.
: Small-sized detected stain divided by the number of times
pre-detection is practiced (average number of detected
lines) will be displayed.
original feed divided by the number of scanning by ADF
(average number of detected lines) will be displayed.
[Counter]
Parts number
Limit value
500,000
AVGR10784U
200,000
Service Manual
12. SERVICE MODE
[ ]
[Parts Counter (Fixed)].
Count condition
1 count for each sheet ejection in
both 1 staple and 2 staple mode.
1 count for each sheet ejection in
saddle stitch mode.
549