Field Service Ver. 2.0 Jul. 2009
19.5.6
C0208: Tray 4 feeder up/down abnormality
Tray 4 upper limit sensor (PS27)
Tray 4 lift-up motor (M24)
Step
1
Check the M24 connector for proper con-
nection and correct as necessary.
2
Check the connector of M24 for proper
drive coupling and correct as necessary.
3
PS27 I/O check, sensor check
4
M24 operation check
5
Change M23
6
Change PFTDB
7
Change PRCB
19.5.7
C0216: LCT up/down abnormality
Upper limit sensor (PS2)
Lift-up motor (M1)
Step
1
Check the M1 connector for proper connec-
tion and correct as necessary.
2
Check the connector of M1 for proper drive
coupling and correct as necessary.
3
PS2 I/O check, sensor check
4
M1 operation check
5
Change M1
6
LUDB ICP2 conduction check
7
Change LUDB
Y110571-1
Relevant parts
Action
Relevant parts
Action
Service Manual
Paper feed/transport drive board (PFTDB)
Printer control board (PRCB)
WIRING DIAGRAM
Control signal
—
—
PFTDB CN18-6 (ON)
PFTDB CN14-1 to 2
—
—
—
LU drive board (LUDB)
WIRING DIAGRAM
Control signal
—
—
LUDB CN5-3 (ON)
LUDB CN3-4 (ON)
—
—
—
19. TROUBLE CODE
Location (Electri-
cal component)
—
—
X-8
X-9
—
—
—
Location (Electri-
cal component)
—
—
LU-204 G-4
LU-204 G-3
—
—
—
761