Unit Change; Software Switch Setting - Olivetti d-Color MF651 Service Manual

Color printer
Hide thumbs Also See for d-Color MF651:
Table of Contents

Advertisement

Field Service Ver. 2.0 Jul. 2009
12.9.5

Unit Change

A. Use
• To select who is to replace a unit.
• Upon setup.
• When the unit life arrives, the warning display is intended for the specific person who is
going to replace the unit.
When "User" is selected
When "Service" is selected : Life warning.
• To set whether or not to display a toner near empty warning.
• Drum unit/K and Developing unit/K are not subject to this setting because they are
replaced by customer engineer.
B. Procedure
<Unit Change>
• The following are the default settings:
Toner Cartridge
Imaging Unit
Waste Toner Box
Punch Dust Box
<Warning Display>
Toner Near Empty : "Yes"
12.9.6

Software Switch Setting

A. Use
• To set the operating characteristic of each function from software switch depending on
what types of printing are normally made.
B. Procedure
1. Touch [Software Switch Setting].
2. Touch [Switch No.] and enter the intended switch number with the ten-key pad.
3. Touch [Bit Assignment].
4. Use [ ] or [ ] to select a bit. To set the bit, enter 0 or 1 with the ten-key pad.
5. To set the bit in hex, touch [HEX Assignment] and use the ten-key pad and [A] to [F]
keys to enter numbers and characters.
6. Touch [Fix].
Y110571-1
: Printing is inhibited.
US, Japan, Others 4
"User"
Service
User
"Service"
User
"Service"
User
"Service"
Service Manual
12. SERVICE MODE
Europe, Others1/2/3
User
"User"
"User"
"User"
No
Service
Service
Service
Service
533

Advertisement

Table of Contents
loading

This manual is also suitable for:

D-color mf551D-color mf451

Table of Contents