Field Service Ver. 2.0 Jul. 2009
(11) Send-SMTP Connection Time-out
<Use>
• To set the timeout period for transmission.
<Procedure>
• The default setting is 60 Sec.
(12) Send-Authentication Setting
<Use>
• To set whether or not to authenticate during transmission via SMTP server.
• To use when authenticating during transmission.
Available authentication mode: POP Before SMTP, SMTP authentication
<Procedure>
• The default setting is OFF.
"OFF"
* Setting to "POP Before SMTP" will set the time for POP Before SMTP.
• The default setting is 60 Sec.
* When setting to SMTP authentication, touch the "Setting Check" key for authentication.
User ID
Password
Domain name : Enter the domain name for SMTP authentication.
(13) TX/RX Test
<Use>
• To determine the correct transmission and reception using CS Remote Care.
<Procedure>
• Press the Start key to let the machine start the transmission and reception test.
• The test procedure and result will be displayed on the screen.
(14) Data Initialization
<Use>
• To initialize the contents for the sever setting.
<Procedure>
• The default setting is No.
Y110571-1
"60 Sec" (30 to 300 Sec)
POP Before SMTP
"60 Sec" (0 to 60 Sec)
: Enter the user ID for SMTP authentication.
: Enter the password for SMTP authentication.
Yes
Service Manual
12. SERVICE MODE
SMTP Authentication
"No"