Cc170: Dynamic Link Error During Starting (Ap0) - Olivetti d-Color MF651 Service Manual

Color printer
Hide thumbs Also See for d-Color MF651:
Table of Contents

Advertisement

19. TROUBLE CODE

19.5.186 CC170: Dynamic link error during starting (AP0)

19.5.187 CC171: Dynamic link error during starting (AP1)
19.5.188 CC172: Dynamic link error during starting (AP2)
19.5.189 CC173: Dynamic link error during starting (AP3)
19.5.190 CC174: Dynamic link error during starting (AP4)
19.5.191 CC180: Dynamic link error during starting (LDR)
19.5.192 CC181: Dynamic link error during starting (IBR)
19.5.193 CC182: Dynamic link error during starting (IID)
19.5.194 CC183: Dynamic link error during starting (IPF)
19.5.195 CC184: Dynamic link error during starting (IMY)
19.5.196 CC185: Dynamic link error during starting (SPF)
19.5.197 CC186: Dynamic link error during starting (OAP)
MFP board (MFPB)
Step
1
If the malfunction code "C-C172" has
occurred, access [Service Mode]
tem 2]
[Image Controller Setting] and
check to see if "Controller 2," "Controller 3,"
or "Others" is set for [Image Controller Set-
ting].
If any of these is set, according to the kind
of controller, select "Controller 0" or "Con-
troller 1."
2
Change MFPB.
3
When not reviving even if the above-men-
tioned procedure is done, contact the
responsible people of KMBT.
19.5.198 CC190: Outline font load error
MFP board (MFPB)
Step
1
Check the hard disk connector for proper
connection and correct as necessary.
2
Format hard disk.
3
Change hard disk
4
Change MFPB.
832
Relevant parts
Action
[Sys-
Relevant parts
Action
Service Manual
Field Service Ver. 2.0 Jul. 2009
NVRAM board (NRB)
WIRING DIAGRAM
Control signal
Hard disk
WIRING DIAGRAM
Control signal
Location (Electri-
cal component)
Location (Electri-
cal component)
Y110571-1

Advertisement

Table of Contents
loading

This manual is also suitable for:

D-color mf551D-color mf451

Table of Contents