Volume Status; A.2 Volume Status - Fujitsu ETERNUS DX60 S3 User Manual

Disk storage systems, all-flash arrays
Hide thumbs Also See for ETERNUS DX60 S3:
Table of Contents

Advertisement

Appendix A Status List

A.2 Volume Status

A.2

Volume Status

Volume status is displayed with an icon and the status name. The volume status is described below.
Status
Available
Spare in Use
Readying
Rebuild
Copyback
Redundant Copy
Partially Exposed Rebuild
Exposed Rebuild
Exposed
Partially Exposed
Not Available
Not Ready
Broken
Data Lost
Unknown
The volume is operating normally.
The RAID group to which the volume belongs manages redundancy by using the hot
spare.
The volume is not formatted.
Rebuilding from a failed data drive to the hot spare or to the replaced drive is being
performed in the RAID group to which the volume belongs.
Copyback from the hot spare to the new data drive is being performed in the RAID
group to which the volume belongs.
Redundant copy to the hot spare is being performed in the RAID group to which the
volume belongs.
Rebuilding from the first failed data drive to the hot spare or to the replaced drive is
being performed in the RAID group to which the volume belongs.
This status is displayed only when the RAID level of the RAID group to which the
volume belongs is "High Reliability (RAID6)" or "High Reliability (RAID6-FR)".
Two of the data drives for the RAID group to which the volume belongs have failed.
Rebuilding from the first failed data drive to the hot spare or to the replaced drive is
being performed. In addition, all the hot spares have already been used. As a result,
the second failed data drive is waiting for the hot spare to become available.
This status is displayed only when the type of the RAID group to which the volume
belongs is "High Reliability (RAID6)" or "High Reliability (RAID6-FR)".
The RAID group to which the volume belongs lost redundancy due to drive failure.
One of the drives that configures the RAID group to which the volume belongs has
failed.
This status is displayed only when the type of the RAID group to which the volume
belongs is "High Reliability (RAID6)" or "High Reliability (RAID6-FR)".
The volume cannot be used.
The RAID group to which the volume belongs is blocked.
The volume is broken.
Data in the volume is lost. Reading or writing of data cannot be performed.
A status other than the ones listed above.
406
ETERNUS Web GUI User's Guide (Operation)
Copyright 2016 FUJITSU LIMITED
Description
P2X0-1260-19ENZ0

Hide quick links:

Advertisement

Table of Contents
loading