Chapter 3 Component Status
3.24 Port Detail
■ Sensor Information
The real time and threshold values (Low/High) for the temperature, voltage, current, transmission
power, and received power are displayed in the Sensor Information.
When the information cannot be obtained, a "-" (hyphen) is displayed.
The target components for this information are FC that have SFPs from which information can be
obtained.
•
An SFP is regarded as being in Warning status when the real time value is lower than the Warning
threshold (Low) and higher than the Alarm threshold (Low).
•
An SFP is regarded as being in Warning status when the real time value is higher than the Warning
threshold (High) and lower than the Alarm threshold (High).
•
An SFP is regarded as being in Alarm status when the real time value is lower than the Alarm
threshold (Low) or higher than the Alarm threshold (High).
-
Temperature
•
Present
The real time temperature of the SFP in the port is displayed.
-
•
Warning
-
•
Alarm
-
-
Voltage
•
Present
The real time voltage of the SFP in the port is displayed.
-
•
Warning
-
•
Alarm
-
x C / y F (x: -128.00 to 128.00, y: -198.40 to 262.40)
Low or High
The Warning threshold (Low/High) for the temperature of the SFP in the port is displayed.
•
x C / y F (x: -128.00 to 128.00, y: -198.40 to 262.40)
Low or High
The Alarm threshold (Low/High) for the temperature of the SFP in the port is displayed.
•
x C / y F (x: -128.00 to 128.00, y: -198.40 to 262.40)
x V (x: 0.00 to 6.55)
Low or High
The Warning threshold (Low/High) for the voltage of the SFP in the port is displayed.
•
x V (x: 0.00 to 6.55)
Low or High
The Alarm threshold (Low/High) for the voltage of the SFP in the port is displayed.
•
x V (x: 0.00 to 6.55)
ETERNUS Web GUI User's Guide (Operation)
Copyright 2016 FUJITSU LIMITED
178
P2X0-1260-19ENZ0