7. HOW TO USE THE POINT TABLE
(2) Starting the servo motor
Click "Operation Start" (b) to rotate the servo motor.
(3) Pausing the servo motor
Click "Pause" (c) to temporarily stop the servo motor.
Click "Operation Start" (b) during a temporary stop to restart the rotation of the remaining travel distance.
In addition, click "Stop" (d) during a temporary stop to clear the remaining travel distance.
(4) Stopping the servo motor
Click "Stop" (d) to stop the servo motor. At this time, the remaining travel distance will be cleared. Click
"Operation Start" (b) to restart the rotation.
(5) Executing a forced stop of the servo motor software
Click "Forced Stop" (e) to make an instantaneous stop. When "Forced Stop" is enabled, "Operation
Start" cannot be used. Click "Forced Stop" again to enable "Operation Start".
(6) Switching to the normal operation mode
To switch from the test operation mode to the normal operation mode, turn off the servo amplifier.

7.1.4 Actual operation

Start actual operation after confirmation of normal operation by test operation and completion of the
corresponding parameter settings.

7.1.5 Troubleshooting at start-up

CAUTION
The following faults may occur at start-up. If any of such faults occurs, take the corresponding action.
"MR-JE-_C" means "MR-JE-_C Servo Amplifier Instruction Manual".
No.
Start-up sequence
1
Power on
Alarm occurs.
Never make a drastic adjustment or change to the parameter values as doing so
will make the operation unstable.
POINT
Using MR Configurator2, you can refer to the reason for rotation failure, etc.
Fault
The 7-segment LED
Not solved even if CN2, CN3, and
display does not turn
CN5 connectors are
on.
disconnected.
The 7-segment LED
Solved when CN2 connector is
display blinks.
disconnected.
Solved when CN3 connector is
disconnected.
Solved when CN5 connector is
disconnected.
(Note)
Investigation
1. Power supply voltage fault
2. The servo amplifier is
malfunctioning.
1. Power supply of encoder
cabling is shorted.
2. Encoder is malfunctioning.
Power supply of the CN3 cabling is
shorted.
Power supply of CN5 cabling is
shorted.
7 - 4
Possible cause
Reference