4. PARAMETERS
No./symbol/
Setting
name
digit
PT21
Set an address decreasing side of the position range output address.
*LNPL
Upper and lower are a set.
Position
Set a range in which POT (Position range) turns on with [Pr. PT19] to [Pr.
range output
PT22].
address -
Set an address in hexadecimal.
(Lower four
digits)
Setting address:
PT22
*LNPH
Position
range output
address -
The unit can be changed to 10
(Upper four
setting of [Pr. PT01].
digits)
Setting range: 00000000h to FFFFFFFFh
PT26
_ _ _ x Electronic gear fraction clear selection
*TOP2
0: Disabled
Function
1: Enabled
selection T-2
Selecting "Enabled" clears the fraction of the previous command by the
electronic gear at start of the automatic operation.
_ _ x _ Current position/command position display selection
Select the display method for the current position and for the command
position.
_ x _ _ For manufacturer setting
x _ _ _ Touch probe 1 function selection
0: Current position latch function by sensor input
1: Interrupt positioning function by sensor input
PT27
_ _ _ x For manufacturer setting
*ODM
_ _ x _ Manual operation method selection
Operation
0: Station JOG operation
mode
1: JOG operation
selection
_ x _ _ For manufacturer setting
x _ _ _
PT28
Set the number of stations per rotation (number of indexer stations).
*STN
Setting "2" or less will be "2".
Number of
stations per
rotation
Setting range: 0 to 255
Upper four
Lower four
digits
STM
Setting
Displayed
Operation
value
data
mode
_ _ 0 _
Display the actual
Auto/
current position with
Positioning
Manual
the machine home
display
position set to 0.
_ _ 1 _
Display the actual
Automatic
Roll feed
current position with
display
automatic operation
start position set to 0.
Manual
Function
digits
[Pr. PT21]
[Pr. PT22]
[μm], 10
[inch], or [pulse] with the
(STM-4)
Status display contents
Current position
Command position
Display the command
current position with
the machine home
position set to 0.
Counting starts from
when the start signal
is on and displays the
command current
position up to the
target position.
When stopping, the
command positions
of the point table are
displayed.
"0" is always
displayed.
4 - 36
General
Initial
Communication
purpose
value
[unit]
CP
PS
CP
0000h
Refer to
Function
column
for unit.
0000h
Refer to
Function
column
for unit.
0h
0h
0h
0h
0h
0h
0h
0h
8
[Stations]
PS