4. PARAMETERS
No./symbol/
Setting
name
digit
PT42
Set a minimum speed for when the digital override function is enabled.
*OVM
When you use the digital override function, multiplication can be set with
[Pr. PT42] and [Pr. PT43]. Set this at the same time with [Pr. PT43].
Digital
override
Refer to the following table for how to calculate multiplication value.
minimum
Setting "0" will be recognized as "1".
multiplication
Setting range: 0 to 100
Note. 0: Off
PT43
Set an override pitch width for when the digital override function is
enabled.
*OVS
When you use the digital override function, multiplication can be set with
Digital
[Pr. PT42] and [Pr. PT43]. Set this at the same time with [Pr. PT 42].
override pitch
width
Refer to the table in [Pr. PT42] for settings.
Setting "0" will be recognized as "1".
Setting range: 0 to 20
Function
Input device (Note)
OV3
OV2
OV1
0
0
0
0
0
0
0
0
1
0
0
1
0
1
0
0
1
0
0
1
1
0
1
1
1
0
0
1
0
0
1
0
1
1
0
1
1
1
0
1
1
0
1
1
1
1
1
1
1: On
Multiplication [%]
OV0
0
Fixed to 100
1
[Pr. PT42]
0
[Pr. PT42] + [Pr. PT43] × 1
1
[Pr. PT42] + [Pr. PT43] × 2
0
[Pr. PT42] + [Pr. PT43] × 3
1
[Pr. PT42] + [Pr. PT43] × 4
0
[Pr. PT42] + [Pr. PT43] × 5
1
[Pr. PT42] + [Pr. PT43] × 6
0
[Pr. PT42] + [Pr. PT43] × 7
1
[Pr. PT42] + [Pr. PT43] × 8
0
[Pr. PT42] + [Pr. PT43] × 9
1
[Pr. PT42] + [Pr. PT43] × 10
0
[Pr. PT42] + [Pr. PT43] × 11
1
[Pr. PT42] + [Pr. PT43] × 12
0
[Pr. PT42] + [Pr. PT43] × 13
1
Fixed to 0
4 - 39
General
Initial
Communication
purpose
value
[unit]
CP
PS
CP
PS
0
[%]
0
[%]