Mitsubishi Electric MR-JE-*C Instruction Manual page 155

General purpose ac servo melservo-je ethernet interface servo amplifier
Hide thumbs Also See for MR-JE-*C:
Table of Contents

Advertisement

7. HOW TO USE THE POINT TABLE
b) Automatic repeat positioning operation by incremental value command method
Example 1. Operations when "10" is set in the auxiliary function of point table No. 4
Position data
Point table No.
[10
STM
μm]
1
4.00
2
5.00
3
10.00
4
5.00
Operation sequence
1) Starting with point table No. 2
2) Executing point table No. 3
3) Executing point table No. 4
4) Re-execute point table No. 2 used at start-up when "10" is set in the auxiliary function of
point table No. 4
5) Repeating the above execution in the sequence of 1), 2), 3), 4), 2), 3), 4)
Forward rotation
Servo motor speed
Reverse rotation
Position address
Target point table
Controlword bit 4
(New set-point)
Point actual value (Note)
M code actual value (Note)
Note. "Point actual value" and "M code actual value" are not outputted in an automatic continuous operation.
Acceleration
Servo motor
time constant
speed [r/min]
1500.00
3000.00
2000.00
1000.00
Point table No. 2
1)
Speed
(3000.00)
0 r/min
5.00
0
ON
OFF
Deceleration
time constant
[ms]
[ms]
200
100
100
150
150
200
300
100
Point table No. 3
2)
Speed
(2000.00)
5.00
7 - 26
Auxiliary
Dwell [ms]
function
150
1
100
3
200
1
150
10
Point table No. 2
Point table No. 4
3)
Speed (1000.00)
Speed
(2000.00)
2)
Point table No. 3
5.00
10.00
15.00
2
M code
1
5
10
15
4)
Speed
(3000.00)
5.00

Hide quick links:

Advertisement

Table of Contents
loading