12. WHEN USING WITH A GENERAL-PURPOSE INTERFACE
Device
Symbol
Manual pulse
TP0
generator
multiplication 1
Manual pulse
TP1
generator
multiplication 2
Analog override
OVR
selection
Point table No.
DI0
selection 1
Point table No.
DI1
selection 2
Point table No.
DI2
selection 3
Point table No.
DI3
selection 4
Point table No.
DI4
selection 5
Point table No.
DI5
selection 6
Point table No.
DI6
selection 7
Point table No.
DI7
selection 8
Connector
pin No.
Select a multiplication of the manual pulse generator.
When a multiplication is not selected, the value set in [Pr. PT03] is enabled.
Device (Note)
TP1
0
0
1
1
Note. 0: Off
1: On
Turning on OVR enables VC (Analog override).
CN3-8
Point table method
Select point tables and homing mode with DI0 to DI7.
DI7
DI6
DI5
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
Note. 0: Off
1: On
Function and application
Manual pulse
generator multiplication
TP0
0
[Pr. PT03] setting value
1
× 1
0
10 times
1
100 times
Device (Note)
DI4
DI3
DI2
DI1
DI0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
1
1
1
1
1
1
1
1
1
12 - 12
division
Selection contents
0
Homing mode
1
Point table No. 1
0
Point table No. 2
1
Point table No. 3
0
Point table No. 254
1
Point table No. 255
Control
I/O
mode
CP
PS
DI-1
DI-1
DI-1
DI-1

Hide quick links: