Mitsubishi Electric MR-JE-*C Instruction Manual page 63

General purpose ac servo melservo-je ethernet interface servo amplifier
Hide thumbs Also See for MR-JE-*C:
Table of Contents

Advertisement

4. PARAMETERS
No./symbol/
Setting
name
digit
PD04
Select input devices to turn on automatically.
*DIA4
When setting the "Command interface selection" of [Pr. PN08] to "_ _ _ 1
(Communication interface)", the setting value of this parameter is invalid.
Input signal
automatic on
_ _ _ x
_ _ _ x (BIN): For manufacturer setting
selection 4
(HEX)
_ _ x _ (BIN): RT (Second acceleration/deceleration selection)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
_ x _ _ (BIN): RTCDP (Second acceleration/deceleration gain selection)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
x _ _ _ (BIN): For manufacturer setting
_ _ x _
_ _ _ x (BIN): For manufacturer setting
(HEX)
_ _ x _ (BIN): For manufacturer setting
_ x _ _ (BIN): For manufacturer setting
x _ _ _ (BIN): For manufacturer setting
_ x _ _
_ _ _ x (BIN): DI0 (Point table No/Next station No. selection 1)
(HEX)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
_ _ x _ (BIN): DI1 (Point table No/next station No. selection 2)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
_ x _ _ (BIN): DI2 (Point table No/next station No. selection 3)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
x _ _ _ (BIN): DI3 (Point table No/Next station No. selection 4)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
x _ _ _
_ _ _ x (BIN): DI4 (Point table No/Next station No. selection 5)
(HEX)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
_ _ x _ (BIN): DI5 (Point table No/Next station No. selection 6)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
_ x _ _ (BIN): DI6 (Point table No/Next station No. selection 7)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
x _ _ _ (BIN): DI7 (Point table No/Next station No. selection 8)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
Function
4 - 26
General
Initial
Communication
purpose
value
[unit]
CP
PS
CP
PS
0h
0h
0h
0h

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents