4. PARAMETERS
No./symbol/
Setting
name
digit
PA06
Set the number of gear teeth on machine side.
CMX
To enable the parameter values in the positioning mode, cycle the power
after setting.
Number of
gear teeth on
Set the electronic gear within the following range.
machine side
(1) 1 ≤ CMX ≤ 16384, 1 ≤ CDV ≤ 16384
(2)
(3) CDV × STN ≤ 32767 (STN: Number of stations per rotation [Pr.
(4) CMX × CDV ≤ 100000
Setting out of the range will trigger [AL. 37 Parameter error].
When a small value is set to the manual operation mode and the JOG
operation mode, the servo motor cannot be driven at the set servo motor
rotation speed.
Travel distance of 1 station = Pt (servo motor resolution) ×
This parameter corresponds to "Motor revolutions (Index: 6091h, Sub:
1)". When this parameter is mapped to the link device of CC-Link IE Field
Network Basic, do not write the parameter value with MR Configurator2,
as the controller overwrites the parameter value written with MR
Configurator2.
Setting range: 1 to 16777215
PA07
Set an electronic gear denominator.
CDV
To enable the parameter, select "Electronic gear (0 _ _ _)" of "Electronic
gear selection" in [Pr. PA21].
Electronic
gear
In the positioning mode, the setting is effective only after rebooting the
denominator
power once the parameter values setup is completed.
(command
pulse
This parameter corresponds to "Shaft revolutions (Index: 6091h, Sub: 2)".
multiplication
When this parameter is mapped to the link device of CC-Link IE Field
denominator)
Network Basic, do not write the parameter value with MR Configurator2,
as the controller overwrites the parameter value written with MR
Configurator2.
Setting range: 1 to 16777215
PA07
Set the number of gear teeth on servo motor side.
CDV
To enable the parameter values in the positioning mode, cycle the power
after setting.
Number of
gear teeth on
Set the electronic gear within the range of [Pr. PA06].
servo motor
Setting out of the range will trigger [AL. 37 Parameter error].
side
This parameter corresponds to "Shaft revolutions (Index: 6091h, Sub: 2)".
When this parameter is mapped to the link device of CC-Link IE Field
Network Basic, do not write the parameter value with MR Configurator2,
as the controller overwrites the parameter value written with MR
Configurator2.
Setting range: 1 to 16777215
1
CMX
≤ 9999
9999
CDV
PT28])
Function
1
STN
4 - 14
General
Initial
purpose
value
[unit]
CP
PS
1
CMX
×
CDV
1
1
Communication