7. HOW TO USE THE POINT TABLE
Example 2. Operations when "9" is set in the auxiliary function of point table No. 2
Position data
Point table No.
[10
μm]
STM
1
5.00
2
6.00
Operation sequence
1) Starting with point table No. 2
2) Executing point table No. 1 when "9" is set in the auxiliary function of point table No. 2
3) Repeating the above execution in the sequence of 1), 2), 1), 2)
Forward rotation
Servo motor speed
Reverse rotation
Position address
Target point table
Controlword bit 4
(New set-point)
Point actual value (Note)
M code actual value (Note)
Note. "Point actual value" and "M code actual value" are not outputted in an automatic continuous operation.
Acceleration
Servo motor
time constant
speed [r/min]
[ms]
3000.00
2000.00
1)
Speed
(2000.00)
0 r/min
Point table No. 2
6.00
0
ON
OFF
Deceleration
time constant
[ms]
100
150
150
200
Point table No. 1
2)
Speed
(3000.00)
5.00
6.00
7 - 31
Auxiliary
Dwell [ms]
function
100
1
200
9
1)
Speed
(2000.00)
6.00
11.00
2
M code
5
10
2)
Speed
(3000.00)
17.00