Transferring The Settings From The Memory Card - Siemens Sinamics G110M Operating Instructions Manual

Sinamics series distributed converter for simogear geared motors
Hide thumbs Also See for Sinamics G110M:
Table of Contents

Advertisement

Data backup and series commissioning
7.1 Backing up and transferring settings using memory card
3. In your drive, select "Drive Navigator".
4. Select the "Commissioning" button.
5. Select the button to transfer the settings to the memory card.
6. Select the settings as shown in the diagram and start the data backup.
7. Wait until STARTER signals that the data backup has been completed.
8. Close the screen forms.
You have backed up the settings of the inverter on the memory card.
7.1.2

Transferring the settings from the memory card

If you wish to transfer the parameter settings from a memory card into the inverter
(download), you have two options:
Automatic download
To automatically upload the parameter settings, you will need to transfer the data from the
memory card as follows:
1. All mains supply and the 24 V external supply.
2. Wait 5 minutes to ensure that any residual power in the system as dissipated.
286
Distributed converter for SIMOGEAR geared motors
Operating Instructions, 09/2017, FW V4.7.9, A5E31298649B AH