Data backup and series commissioning
7.5 Know-how protection
Deactivating know-how protection, deleting a password
Procedure with STARTER
Proceed as follows to deactivate know-how protection:
1. Go online with STARTER.
2. Select the required inverter in the project.
3. Using the right-hand mouse key, open the dialog window "Know-how protection drive unit
→ Deactivate...".
4. Select the required option:
– Temporary status: Know-how protection is again active after switching off the power
– Final status: Also select "Copy RAM to ROM".
5. Enter the password for know-how protection.
6. Exit the screen form with OK.
You have deactivated know-how protection.
Parameter
Parameter
r7758[0...19]
p7759[0...19]
r7760
p7765
300
supply and switching on again.
The inverter deletes the password. However, after switching off and switching on the
power supply, the password remains deleted.
Description
KHP Control Unit serial number
KHP Control Unit reference serial number
Write protection/know-how protection status
.01
1 signal: Know-how protection active
.02
1 signal: Know-how protection temporarily unlocked
.03
1 signal: Know-how protection cannot be deactivated
.04
1 signal: Extended copy protection active
.05
1 signal: Basic copy protection active
.06
1 signal: Trace and measurement functions for diagnostic purposes active
KHP configuration
Distributed converter for SIMOGEAR geared motors
Operating Instructions, 09/2017, FW V4.7.9, A5E31298649B AH