Siemens Sinamics G110M Operating Instructions Manual page 43

Sinamics series distributed converter for simogear geared motors
Hide thumbs Also See for Sinamics G110M:
Table of Contents

Advertisement

Terminal Housing dimensions and fixing points
The Terminal Housing of the G110M system replaces the existing terminal box on the
connected motor. There are three different types of the Terminal Housings and they are
shown in the following figure. All three Terminal Housings have the same external
dimensions:
● Height: 92 mm.
● Width: 161 mm
● Depth: 171 mm
Please note that the fixing points (for securing the Terminal Housing to the motor) are
indicated in RED. The FS 80/90 Terminal Housing has six fixing points, two of which are
marked in GREEN and indicated by the ground symbol. These fixing points provide the
correct earthing between the Terminal Housing and the motor and MUST be used.
All fixing bolts for the Terminal Housing are supplied with each Terminal Housing.
Note
FS 80/90 Terminal Housing 21 mm fixing screws
The 21 mm fixing screws for the FS 80/90 Terminal Housing are not supplied with the
product.
Figure 4-3
Motor dimensions
There are a large number of motors associated with the G110M system, with each motor
being uniquely configured for the user requirements.
Distributed converter for SIMOGEAR geared motors
Operating Instructions, 09/2017, FW V4.7.9, A5E31298649B AH
Terminal Housing dimensions
Installation
4.1 Mechanical Installation
43