Figure 6-4
As previously mentioned, parameter p0756 can be modified to change the type of analog
input. The default settings for parameter p0756 and its default settings are given in the
following table.
Analog input
AI0
AI1
The complete settings available for parameter p0756 are shown below.
0:
1:
2:
3:
9:
If you change the analog input type using p0756, then the inverter automatically selects the
appropriate scaling of the analog input.
You can define your own characteristic that matches your particular application. The linear
scaling characteristic is defined using two points (p0757, p0758) and (p0759, p0760).
Parameters p0757 ... p0760 are assigned to an analog input via their index, e.g. parameters
p0757[0] ... p0760[0] belong to analog input 0.
Figure 6-5
Distributed converter for SIMOGEAR geared motors
Operating Instructions, 09/2017, FW V4.7.9, A5E31298649B AH
Analog DIP Switch
Unipolar voltage input
Unipolar voltage input
Unipolar voltage input
Unipolar voltage input monitored
Unipolar current input
Unipolar current input monitored
Unipolar voltage input
Scaling characteristics
6.3 Adapt the default setting of the inputs and outputs
Value range
0 V ... +10 V
0 V ... + 10 V
0 V ... +10 V
+2 V ... +10 V
0 mA ... +20 mA
+4 mA ... +20 mA
0 V ... +3 V
Advanced commissioning
Parameter default settings
p0756 [0] = 0
p0756 [1] = 0
147