Characteristics Of U/F Control - Siemens Sinamics G110M Operating Instructions Manual

Sinamics series distributed converter for simogear geared motors
Hide thumbs Also See for Sinamics G110M:
Table of Contents

Advertisement

Advanced commissioning
6.17 Motor control
6.17.1.1

Characteristics of U/f control

The inverter has different V/f characteristics.
Figure 6-47
The inverter increases its output voltage to the maximum possible output voltage. The
maximum possible output voltage of the inverter depends on the line voltage.
When the maximum output voltage is reached, the inverter only increases the output
frequency. At this point, the motor enters the field weakening range: At constant torque, the
slip decreases quadratically as the speed increases.
234
The voltage boost of the characteristic optimizes the speed control at low speeds
With the flux current control (FCC), the inverter compensates for the voltage drop in the stator
resistor of the motor
Characteristics of V/f control
Distributed converter for SIMOGEAR geared motors
Operating Instructions, 09/2017, FW V4.7.9, A5E31298649B AH

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents