Installation
4.3 Electrical Installation
– As a conductor of a multi-conductor cable, the protective conductor has a cross-
– For an individual conductor, the protective conductor has a cross-section ≥ 10 mm²
– The protective conductor consists of two individual conductors with the same cross-
● When connecting a multi-conductor cable using an industrial plug connector according to
EN 60309, the protective conductor must have a cross-section of ≥ 2.5 mm² Cu.
4.3.4

Connection and cables

The following block diagrams and tables describe the details and limitations of the
connections on the converter.
Wiring stripping
The following components are delivered with pre-prepared cables and no wire stripping is
necessary:
● Internal 24 V DC power supply
● Internal braking resistor for FSA
● Internal braking resistor for FSB
● Motor EM brake
● The motor terminals for the terminal housing (for connection to the motor terminals).
All other connections to the Phoenix mains and motor connectors need to be stripped to a
length of 10 mm, with a maximum torque of 0.8 Nm.
Cable lengths
The maximum cable lengths for all the converters are shown in the following table.
Table 4- 4
Cable
Digital inputs
Digital outputs
Analog input
Motor cable with Wall Mount Kit
The maximum cable lengths for communications are determined by a number of factors, for
example, the maximum length of the cable for USS and PROFIBUS are dependent on the
data transfer rate being utilized by the network.
70
(Cables routed inside electrical cabinets or enclosed machine housings are
considered to be adequately protected against mechanical damage.)
section ≥ 2.5 mm² Cu.
Cu.
section.
Maximum cable lengths
Screening
Unscreened
Unscreened
Screened
Distributed converter for SIMOGEAR geared motors
Operating Instructions, 09/2017, FW V4.7.9, A5E31298649B AH
Max. length
15 m (49 ft)
15 m (49 ft)
15 m (49 ft)
5 m (16.40 ft)

Hide quick links: