Advertisement

Automatic Operation (Positioning Control)

7.1.2 Setting and Operation of E-Point Control

The example below is a case of single-axis control with the positioning unit installed in slot 1.
The movement amount setting uses an increment method in pulses.
 Settings
Items
Operation pattern
Control method
X-axis movement amount
Acceleration/deceleration pattern
Acceleration time (ms)
Deceleration time (ms)
Target speed
 Operation diagram
f [pps]
10000
500
Positioning start contact Y110
BUSY flag X118
Operation done flag X120
Current value
 Operation of each contact
• The BUSY flag (X118), which indicates that the motor is running, will turn ON when the
positioning control starts, and it will turn OFF when the operation completes.
• The operation done flag (X120), which indicates the completion of operation, will turn ON
when the current operation is completed, and it will be held until the next positioning control,
JOG operation, home return, or pulser operation starts. The flag will turn ON after the
positioning unit transmits a reference for the target position.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
7-4
E: End point
I: Increment
10000 pulses
L: Linear
100 ms
100 ms
10000 pps
10000 pulses
100
20000
Setting example
100
t [ms]