Offset
Name
address
008H
Positioning
movement amount
009H
04AH
Auxiliary point
00BH
00CH
Dwell Time
Auxiliary output
00DH
code
00EH
00FH
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
17.6 Details of Each Axis Setting Area in Unit Memory
Default
The setting area for the positioning movement amount for positioning
operation.
The amount of increment movement or absolute coordinates will be set
according to the control code settings.
Setting range: -1,073,741,823 to 1,073,741,823
Any other settings will be errors.
Set the following range according to the unit setting.
0
Pulse: -1,073,741,823 to 1,073,741,823 pulses
μm (0.1 μm): -107,374,182.3 to 107,374,182.3 μm
μm (1 μm): -1,073,741,823 to 1,073,741,823 μm
inch (0.00001 inch): -10,737.41823 to 10,737.41823 inches
inch (0.0001 inch): -107,374.1823 to 107,374.1823 inch
degree (0.1 degree): -107,374,182.3 to 107,374,182.3 degrees
degree (1 degree): -1,073,741,823 to 1,073,741,823 degrees
The setting area for auxiliary points (center and passing points) in the
case of circular interpolation or spiral interpolation operation.
Setting range: -1,073,741,823 to 1,073,741,823
Any other settings will be errors.
Set the following range according to the unit setting.
Pulse: -1,073,741,823 to 1,073,741,823 pulses
0
μm (0.1 μm): -107,374,182.3 to 107,374,182.3 μm
μm (1 μm): -1,073,741,823 to 1,073,741,823 μm
inch (0.00001 inch): -10,737.41823 to 10,737.41823 inches
inch (0.0001 inch): -107,374.1823 to 107,374.1823 inch
degree (0.1 degree): -107,374,182.3 to 107,374,182.3 degrees
degree (1 degree): -1,073,741,823 to 1,073,741,823 degrees
On completion of the positioning of this table, the operation of the next
table will start after stopping the motor for the dwell time in the case of
the continuance point (C-point), the dwell time will be ignored in the
case of the passing point (P-point), and the positioning done contact will
turn ON after a pause of the dwell time in the case of end point (E-point)
0
control.
Setting range: 0 to 32,767 (ms)
Any other settings will be errors.
Make auxiliary output mode settings for the parameter setting area to
specify data to be output to the auxiliary output codes for the each axis
information & monitor area.
0
No setting ranges, in particular.
Setting range and description
17-51