Specifications
Offset address
Name
02EH
02FH
030H
031H
032H
Emergency
stop
033H
deceleration
time
034H
Limit stop
035H
deceleration
time
036H
Error stop
037H
deceleration
time
Pulser
038H
operation
setting code
Pulser
039H
operation ratio
numerator
Pulser
03AH
operation ratio
denominator
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
17-46
Default
This parameter will be enabled if an emergency stop request is made with
I/O, and the deceleration of the positioning unit will be completed in the
specified deceleration time.
100
Setting range: 0 to 10,000 (ms)
Any other settings will be errors.
This parameter will be enabled if limit input is ON while the positioning unit
is in operation, and the deceleration of the positioning unit will be
completed in the specified deceleration time.
100
Setting range: 0 to 10,000 (ms)
Any other settings will be errors.
This parameter will be enabled if an error occurs, and the deceleration of
the positioning unit will be completed in the specified deceleration time.
100
Setting range: 0 to 10,000 (ms)
Any other settings will be errors.
If a pulse operation request is made with I/O, select the desired pulser
input from pulser inputs 1 to 4.
0: Pulser input 1
0
1: Pulser input 2
2: Pulser input 3
3: Pulser input 4
Any other settings will be errors.
Set a multiplier for the input pulse train for the operation of the pulser.
The number of reference pulses is obtained from the pulse train input from
the pulser multiplied by the numerator of the pulser operation
1
ratio/denominator of pulser operation ratio.
Setting range: 1 to 32,767
Any other settings will be errors.
Set a divisor for the input pulse train for the operation of the pulser.
The number of reference pulses is obtained from the pulse train input from
the pulser multiplied by the numerator of the pulser operation
1
ratio/denominator of pulser operation ratio.
Setting range: 1 to 32,767
Any other settings will be errors.
Setting range and description