17.4.9 Warning Annunciation & Clear Area
If warnings (not involving a stoppage) occur, data on the warnings along with the number of
warnings will be stored on an axis-by-axis basis in this area. If the warning clear is executed,
the warnings and the number of warnings occurred will be cleared once. Then warnings will
be judged again. Therefore, the same warnings will occur if the warning conditions continue.
The number of warnings for each axis is annunciated. If a total warning occurs, the data on all
the axes will be stored in the warning annunciation buffer. Up to 7 warnings are stored in the
warning log.
Warnings can be cleared not only in this area but also with the warning clear contact.
Unit
memory no. (Hex)
UM 001A9
UM 001C1
UM 001C2
UM 001C3
UM 001C4
UM 001C5
UM 001C6
UM 001C7
UM 001C8
UM 001C9
UM 001CA
UM 001CB
UM 001CC
UM 001CD
UM 001CE
UM 001CF
UM 001D1
UM 001D2
UM 001D3
UM 001D4
UM 001D5
UM 001D6
UM 001D7
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Name
Warning clear settings on
axis-by-axis basis
No. of occurrences of
warnings
1st axis warning code
annunciation buffer 1
1st axis warning code
annunciation buffer 2
1st axis warning code
annunciation buffer 3
1st axis warning code
annunciation buffer 4
1st axis warning code
annunciation buffer 5
1st axis warning code
annunciation buffer 6
1st axis warning code
annunciation buffer 7
No. of occurrences of
warnings on the 2nd axis
2nd axis warning code
annunciation buffer 1
2nd axis warning code
annunciation buffer 2
2nd axis warning code
annunciation buffer 3
17.4 Details of Common Area in Unit Memory
Clears warnings on an axis-by-axis basis
bit
Name
0
Warning clear on 1st axis
1
Warning clear on 2nd axis
2
Warning clear on 3rd axis
3
Warning clear on 4th axis
15 to 4
Annunciates the number of occurrences of warnings on the 1st
axis
The latest warning codes are stored in order from buffer number
1.
Annunciates the number of occurrences of warnings on the 2nd
axis
A code will be annunciated if a warning occurs.
A code will be annunciated if a warning occurs.
A code will be annunciated if a warning occurs.
Description
Default
Description
0: No warning clear
0
0 to 1: Warning
0
clear executed
0
(The positioning
0
unit will set the
value to 0
automatically
after execution.)