Panasonic FP7 User Manual page 187

Positioning unit
Hide thumbs Also See for FP7:
Table of Contents

Advertisement

Error
Error name
code
Synchronous
B045H
axis difference
check warning
Automatic
movement
B046H
amount check
warning
Recalculation
B304H
error warning
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Description
The difference between
the movement amounts
of the target axes in
synchronous operation
has exceeded the
specified difference
threshold.
This warning occurs
when the synchronous
operation mode and
synchronous difference
check function are set
to Warning.
The automatic
movement amount
check function has
detected that the
difference between the
instruction value and
feedback value is in
excess of the preset
automatic movement
amount.
This warning occurs
when the operation of
the automatic check
function of movement
amount is set to
Warning.
An error has occurred
while recalculation
processing is in
process.
15.4 List of Warning Codes
Object
Recovered
Each
Check the operation of the target
Yes
axis
axes for the synchronous operation.
Each
Check the operation of the target
Yes
axis
axes.
Each
Check the settings for each axis
Yes
axis
parameter and interpolation group.
Countermeasures
15-15

Advertisement