Set Value Error (From 4000H) - Panasonic FP7 User Manual

Positioning unit
Hide thumbs Also See for FP7:
Table of Contents

Advertisement

15.3.3 Set Value Error (from 4000H)

The following errors occur to various set values made in the positioning setting menu of the
programming tool and ladder programs.
Error
Error name
code
The settings of axis
4000H
groups are not
correct
4002H
Unit setting error
Pulse number error
4004H
per rotation
Movement amount
4005H
error per rotation
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Description
The settings of axis
groups are not correct.
The unit system for the
axis setting is out of the
range.
The pulse number is out
of the range.
The movement amount
is out of the range.
Object
Recovered
Each axis
Yes
Each axis
Yes
Each axis
Yes
Each axis
Yes
15.3 Error Code Table
Countermeasures
Check the following items in the
settings of the axis group and
independent axis.
• The same axis number has
been registered in more than
one group.
• Four or more axes have been
set in one group.
• The group is composed of
one axis only.
Check if the unit is one of the
followings.
pulse, µm, inch, degree
Check the set value.
If the set value is out of the
range, reduce it by the
following formula.
(Pulse number per rotation) /
(Movement amount per
rotation)
15-9