Transfer Of Parameters; Writing Parameters To Unit - Panasonic FP7 User Manual

Positioning unit
Hide thumbs Also See for FP7:
Table of Contents

Advertisement

Transfer to Unit and Commissioning

6.2 Transfer of Parameters

6.2.1 Writing Parameters to Unit

• Information on parameters that have been set is transferred as a part of project information
to the CPU unit along with other configuration information.
• The following procedure is explained on the condition that the Configurator PM7 has already
started.
PROCEDURE
1. Select "File" → "Exit" from the menu bar of the Configurator PM7.
2. When "Save data in the configuration area?" appears, press [Yes(Y)].
3. Press the [OK] button in the FP7 configuration dialog box.
4. Select "Online" → "Download to PLC" from the FPWIN GR7 menu bar.
Parameters for the positioning unit will be downloaded to the CPU unit along with
the program and other configuration information.
5. Set the FP7 CPU unit to RUN mode.
The configuration information will be transferred to the positioning unit as well so
that the positioning unit will be read for commissioning with I/O signals or the
Configurator PM7.
6. Select "Option" → "FP7 configuration" from the menu bar.
The FP7 configuration dialog box will be displayed.
7. Select "I/O map" from the left pane.
8. Select the positioning unit from the I/O map and press the [Advanced
settings (A)] button.
The Configurator PM7 will be activated.
Select [Online] → [Data monitor] → [Status display] → [Tool operation] so that
each menu items of the positioning unit will be available.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com