Panasonic FP7 User Manual page 242

Positioning unit
Hide thumbs Also See for FP7:
Table of Contents

Advertisement

Specifications
Offset
Name
address
002H
003H
Positioning
004H
acceleration
time
Positioning
005H
deceleration
time
006H
Positioning
target speed
(Interpolation
speed)
007H
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
17-50
Default
The setting area for acceleration time and deceleration time for positioning
operation.
Different settings can be made for acceleration and deceleration.
The settings for the axis with the smallest number in the axis group are
100
enabled for interpolation operation.
Setting range: 0 to 10,000 (ms)
Any other settings will be errors.
The target axis will operate at target speed in the case of single axis operation
and operate at target interpolation speed in the case of interpolation operation.
The settings for the axis with the smallest number in the axis group are
enabled for interpolation operation.
Setting range: 1 to 32,767,000
1000
Any other settings will be errors.
Set the following range according to the unit setting.
Pulse: 1 to 32,767,000 pps
μm: 1 to 32,767,000 μm/s
inch: 0.001 to 32,767.000 inch/s
degree: 0.001 to 32,767.000 rev/s
Setting range and description