9.7.1 Automatic measurement

Menu
Top→INPUT TIMING→AUTO SETUP
Setting for
Each input channel, each input signal (only analog input signal)
Setting value
・NORMAL MODE [Default]
・NEXT ASPECT
Analog RGB/analog YPbPr input video is measured to set "9.7.2 The total number of horizontal
dots", "9.7.3 Start position", "9.7.4 Active area" , and "9.7.9 Tracking" automatically.
●Can be measured:
 - Input video contacts the circumscribed rectangle.
 - Brightness of input video is 25% or more.
Input video
Valid display
area
By selecting "NORMAL MODE", the MSD performs automatic measurement of the start position and active
area. If edges of video are not displayed correctly, use this mode to set the start position and active area
automatically.
If the input video is not recognized correctly
like above, it can adjust by executing
"NORMAL MODE" automatic input
measurement.
MSD-701UHD / 702UHD / 801UHD/ 802UHD User's Guide
・4:3
・5:4
Input video
[Fig. 9.12] Conditions of automatic measurement
[Fig. 9.13] Automatic measurement by "NORMAL MODE"
・5:3
・16:10
・16:9
●Cannot be measured:
 - Right and left sides of input video do not touch the circumscribed
rectangle.
 - Brightness of input video is 24% or less.
Input video
If the setting of active area is not correct
and it cannot adjust only by starting
position, the active area is also adjusted by
executing automatic input measurement.