9.17.9
Viewing sink device EDID
Menu
Top→OTHERS→EDID STATUS
Values to be displayed [Table 9.49] Sink device EDID
You can display EDID information of the sink device that is connected to the video output connector.
・HDMI supported sink device
・Non-HDMI-supported sink device : No.1 and No.2
If no sink device is connected, the VFD screen shows "UNCONNECTED". If the MSD cannot read EDID from
connected sink devices, the VFD screen shows "EDID READ ERROR".
No.
Display
[OUT1A]xxxx
1920x1080 148.50MHz
Upper
Monitor name
Lower
Resolution, dot clock
No.
Display
[OUT1A]
32/44.1/48/96kHz
-
Upper
Lower
Audio sampling frequency
MSD-701UHD / 702UHD / 801UHD/ 802UHD User's Guide
: No.1 to No.6
[Table 9.49] Sink device EDID
1
[OUT1A]HDMI
RGB/422/444/420
[OUT1A]
DVI
HDMI or nothing is displayed
Sampling structure
RGB : RGB
422 : YCbCr 4:2:2
444 : YCbCr 4:4:4
420 : YCbCr 4:2:0
or
Non-HDMI-supported sink
device
DVI : DVI device
4
[OUT1A]16/20/24BIT
8CHANNEL COMPRESSED
Audio bit length
Number of audio channels,
compressed audio
supported/not supported
("COMPRESSED")
2
[OUT1A]
24BIT COLOR
-
Color depth
5
[OUT1A]
HDR:-- / SCDC:ON
-
HDR and SCDC supported/not
supported
3
6
131