Signallings

184 | © 2017 ABB | 1SDH001330R0002 - ECN000058721 Rev. A
Continued from the previous page
The following table shows the configuration parameters of the modules:
Parameter
Values
Voltage
Absent, Present
Transf.
100 V, 115 V, 120 V, 190 V, 208 V,
220 V, 230 V, 240 V, 277 V, 347 V,
Rated voltage
380 V, 400 V, 415 V, 440 V, 480 V,
500 V, 550 V, 600 V, 660 V, 690 V
100 V, 115 V, 120 V, 190 V, 208 V,
220 V, 230 V, 240 V, 277 V, 347 V,
Primary
380 V, 400 V, 415 V, 440 V, 480 V,
voltage
500 V, 550 V, 600 V, 660 V, 690 V,
910 V, 950 V, 1000 V, 1150 V
Secondary
100 V, 110 V, 115 V, 120 V, 200 V,
voltage
230 V
Power flow
Bottom->Top, Top->Bottom
Neutral
Absent, Present
connection
The following table shows the path from the display to get information on the modules:
About
The items of information on the modules that can be displayed are the serial number and the version ("Basic"
in the case of Ekip Measuring, "Pro" in the case of Ekip Measuring Pro).
The following table shows the possible signals, and their meaning:
Pos.
Description
Power status LED, green; present only on the Ekip Measuring Pro. The possible states are:
A
A
• Off: the power supplied by the Ekip Measuring Pro to the trip unit is absent.
• On fixed: the power supplied by the Ekip Measuring Pro to the trip unit is present.
Default
Absent
400 V
400 V
100 V
Low->High
Present
Protection Unit
Circuit-breaker
Modules
Power Controller
Electronic accessories | 3 - Ekip Measuring modules
ABB | SACE Emax 2
Description
• Absent = Isolation transformer on
the supply side of the inputs of the
module is absent.
• Present = Isolation transformer on
the supply side of the inputs of the
module is present.
Displayed with "Voltage Transf." set
as absent: the rated voltage of the
installation.
Displayed with "Voltage Transf." set
as present: the primary voltage of
the isolation transformer.
Displayed with "Voltage Transf." set
as present: the secondary voltage of
the isolation transformer.
• Bottom->Top = Flow of power
from the low terminals to the high
terminals of the circuit-breaker (load
connected to top).
• Top->Bottom = Flow of power
from the high terminals to the low
terminals the circuit-breaker (load
connected to bottom).
• Present = It enables measurement
of the phase voltages.
• Absent = It disables measurement
of the phase voltages (only it
enables measurement of line-to-line
voltages).
...
Ekip Measuring
...