Advanced Menus - ABB SACE Emax E1.2 Operating Instructions For The Design Engineer

Sace emax 2 series low voltage air circuit-breakers
Hide thumbs Also See for SACE Emax E1.2:
Table of Contents

Advertisement

Advanced menus The following table shows the submenus and the protections associated to the menu Advanced, and the
48 | © 2017 ABB | 1SDH001330R0002 - ECN000058721 Rev. A
relevant Ekip Touch trip units.
IMPORTANT:
• Selecting a protection opens the list of the parameters that can be set for the
selected protection.
• With Hi-Touch and G Hi-Touch trip units, and the Dual Set function enabled (see
the Settings menu), the protections can be set according to two configurations (Set
A and Set B), from which the default configuration can be selected.
Advanced
S(V) Protection
S2(V) Protection
MCR Protection
D Protection
IU Protection
Rc Protection
UV Protection
UV2 Protection
OV Protection
OV2 Protection
RV Protection
VU Protection
• Set A
(1)
UF Protection
• Set B
(1)
UF2 Protection
OF Protection
OF2 Protection
ROCOF Protection
RP Protection
RQ ProtectioN
OP Protection
OQ Protection
UP Protection
Synchrocheck
Alarms
Current thresholds
External Trip
• Functions
Trip RESET
Switch On SET B
(1)
Submenus available with Hi-Touch and G Hi-Touch trip units, and the Dual Set function enabled (see the
Settings menu).
(2)
Protection available with Rating Plug Rc and Ekip Measuring Pro modules, and toroid Rc (see the menu
Settings, Circuit Breaker, Ground protection), and alternative to the Gext protection (see the Protections menu).
(3)
Protection available with Ekip Measuring Pro module.
(4)
Protection available with the Ekip Synchrocheck module.
(5)
It opens a list of the parameters that can be set for programming the opening of the circuit-breaker.
(6)
It opens a list of the parameters that can be set for programming the reset of the tripping signal.
(7)
It opens a list of the parameters that can be set for programming the switching of the protection configuration
from A to B.
Trip units
-
-
Touch
-
Touch
(2)
Touch
(3)
-
Touch
(3)
-
-
Touch
(3)
Touch
(3)
-
Touch
(3)
-
-
Touch
(3)
-
-
-
-
Touch
(4)
(3)
Touch
(3)
(5)
Touch
(6)
(7)
ABB | SACE Emax 2
-
G-Touch
-
-
G-Touch
-
G-Touch
Hi-Touch
-
G-Touch
-
-
G-Touch
Hi-Touch
-
G Hi-Touch
G-Touch
-
-
-
Hi-Touch
-
-
-
-
G-Touch
Hi-Touch
Ekip Touch protection trip unit | 6 - Menu