Access From The Display - ABB SACE Emax E1.2 Operating Instructions For The Design Engineer

Sace emax 2 series low voltage air circuit-breakers
Hide thumbs Also See for SACE Emax E1.2:
Table of Contents

Advertisement

Access from the display With the trip unit energized, the presence of the modules activates the following on the display:
181 | © 2017 ABB | 1SDH001330R0002 - ECN000058721 Rev. A
• Additional graphical pages, that display measurements.
• Additional menus.
The additional graphical pages are:
• A summary of the measurements in progress (maximum phase current, maximum phase-to-phase voltage,
power factor, and the active, reactive and apparent power), accessible from the page Histograms (see
page 42).
• The indicators of the maximum phase-to-phase voltage, and of the active, reactive and apparent power,
accessible by selecting the pages Measuring instruments (see page 44).
• The measurements of the phase and phase-to-phase voltages, and of the active, reactive and apparent
power, as well as the energy counters, accessible by selecting the pages Measurements (see page 45).
• The historicals of the minimum and maximum phase-to-phase voltages and maximum and mean power,
accessible from the menu Measurements.
• The waveforms and the harmonics of the phase-to-phase voltages, accessible from the menu Measurements.
The additional menus allow you to:
• Configure the protections activated by Ekip Measuring Pro.
• Configure the modules.
• Display the measurements associated to the modules (in addition to those displayed in the graphical pages).
• Display information on the modules.
The following table shows the path from the display to access the configuration parameters of the protections
activated by the Ekip Measuring Pro module:
Advanced
(1)
Protection available with Rating Plug Rc and Ekip Measuring Pro, and toroid Rc (see the menu Settings -
Circuit Breaker - Ground protection), and alternative to the Gext protection (see the Protections menu).
...
IU Protection
Rc Protection
(1)
UV Protection
UV2 Protection
OV Protection
OV2 Protection
RV Protection
VU Protection
UF Protection
UF2 Protection
OF Protection
OF2 Protection
ROCOF Protection
RP Protection
RQ Protection
OP Protection
OQ Protection
UP Protection
Synchrocheck Protection
Signallings
Current thresholds
...
ABB | SACE Emax 2
Phase Sequence
Cos Ø
Continued on the next page
Electronic accessories | 3 - Ekip Measuring modules