ABB SACE Emax E1.2 Operating Instructions For The Design Engineer page 179

Sace emax 2 series low voltage air circuit-breakers
Hide thumbs Also See for SACE Emax E1.2:
Table of Contents

Advertisement

173 | © 2017 ABB | 1SDH001330R0002 - ECN000058721 Rev. A
Continued from the previous page
Symbol
Description
*
See the note indicated by the letter
A1
Applications located on the mobile part of the circuit-breaker
A3
Applications located on the fixed part of the circuit-breaker
Indicative device and connections for control and signalling, outside the
A4
circuit-breaker
BUS1
Serial interface with external bus
D
Electronic time-lag device of YU undervoltage coil, outside the circuit-breaker
F1
Time-delayed trip fuse
GZi(DBi)
Zone Selectivity input for G protection or input in "reverse" direction for D protection
Zone Selectivity output for G protection or output in "reverse" direction for D
GZo(DBo)
protection
I 01...32
Up to 10 programmable digital inputs of the Ekip trip unit
K51
Overcurrent protection solid-state trip unit
K51 / COM
Communication module
K51 / MEAS
Measurement module
K51 / SIGN
Signalling module
K51 / SUPPLY
Optional auxiliary power supply module (24-48Vdc and 110-220Vac / dc)
K51 / SYNC
Synchronization module
K51 / YC
Closing control from the Ekip protection trip unit
K51 / YO
Opening control from the Ekip protection trip unit
M
Motor for loading closing springs
O 01...32
Up to 10 programmable digital inputs of the Ekip trip unit
O SC
Contact for synchronism control
Q
Circuit-breaker
Q / 1...Q / 27
Auxiliary open/closed contacts of the circuit-breaker
Rc
Rc Toroid
RTC EKIP
Auxiliary ready to close contact of the circuit-breaker, used internally by the trip unit
RTC
Contact for signalling circuit-breaker is ready to close
S33M / 1...2
Limit contacts of spring loading motor
S43
Switch for setting remote/local control
S51
Trip signalling contact
Contacts for signalling circuit-breaker in disconnected position
S75E / 1...4
(only with withdrawable circuit-breakers)
Contacts for signalling circuit-breaker in connected position
S75I / 1...5
(only with withdrawable circuit-breakers)
Contacts for signalling circuit-breaker in test position
S75T / 1...2
(only with withdrawable circuit-breakers)
SC
Pushbutton or contact for closing the circuit-breaker
SO
Pushbutton or contact for immediate opening of the circuit-breaker
SO1
Pushbutton or contact for opening the circuit-breaker with time-delayed trip
SR
Pushbutton or contact for electrical resetting of S51 trip contact
Input for Zone Selectivity for S protection or input in "direct" direction for D
SZi(DFi)
protection
Output for Zone Selectivity for S protection or output in "direct" direction for D
SZo(DFo)
protection
TI / L1
Current transformer phase L1
TI / L2
Current transformer phase L2
TI / L3
Current transformer phase L3
TI / N
Current transformer on neutral
TU1...TU2
Insulation voltage transformer (outside circuit-breaker)
Uaux
Auxiliary supply voltage
UI / L1
Current sensor phase L1
ABB | SACE Emax 2
Continued on the next page
Accessories | 2 - Wiring diagrams