Alcatel 5620 Troubleshooting Manual page 75

Service aware manager
Table of Contents

Advertisement

Alarm name, ID, type, and default
probable cause
Name: Software Initializing
ID: 110
Type: Software Alarm
Probable cause: software Initializing
Name: Software Upgrade Failed
ID: 106
Type: Configuration Alarm
Probable cause: file Access Error
(2 of 2)
Alarm name, ID, type, and default
probable cause
Name: Ber Line Signal Degradation
ID: 88
Type: Communications Alarm
Probable cause: Ber Line Signal Degradation
Name: Ber Line Signal Failure
ID: 89
Type: Communications Alarm
Probable cause: Ber Line Signal Failure
Name: Line Alarm Indication Signal
ID: 84
Type: Communications Alarm
Probable cause: Line Alarm Indication Signal
Name: Line Error Condition
ID: 94
Type: Communications Alarm
Probable cause: line Error Condition
Name: Line Remote Defect Indication
ID: 85
Type: Communications Alarm
Probable cause: line Remote Defect
Indication
Name: Loss Of Clock
ID: 83
Type: Communications Alarm
Probable cause: Loss Of Clock
(1 of 3)
Alcatel 5620 Service Aware Manager, Release 2.1 R2
May 2005
95-5887-01-00-B
Default Severity, object type
Severity: warning
Object type: Card Software
Domain: sw
Severity: major
Object type: Backup Restore
Manager
Domain: sw
Table 3-28 SONET equipment (sonetequipment) alarms
Default Severity, object type
Severity: major
Object type: Sonet Port Specifics
Domain: sonetequipment
Severity: major
Object type: Sonet Port Specifics
Domain: sonetequipment
Severity: major
Object type: Sonet Port Specifics
Domain: sonetequipment
Severity: major
Object type: Sonet Port Specifics
Domain: sonetequipment
Severity: major
Object type: Sonet Port Specifics
Domain: sonetequipment
Severity: major
Object type: Sonet Port Specifics
Domain: sonetequipment
3 — Troubleshooting network alarms
Additional information
The software upgrade using the
5620 SAM failed.
Additional information
lb2er-sd reports line signal
degradation BER errors. Use the
threshold command to set the error
rate(s) that when exceeded
determine signal degradation and
signal failure. When configured,
lb2er-sd alarms are raised and
cleared. These alarms are not
issued by default.
lb2er-sf reports line signal failure
BER errors. Use the threshold
command to set the error rate(s) that
when exceeded determine signal
degradation and signal failure.When
configured, lb2er-sf alarms are
raised and cleared. These alarms
are issued by default.
Reports line alarm indication signal
LAIS errors. When configured, LAIS
alarms are raised and cleared.
Reports a line error condition raised
by the remote as a result of b1 errors
received from this node. When
configured, LREI traps are raised
but not cleared.
Reports line remote defect indication
errors. LRDIs are caused by remote
LOF, LOC, LOS. When configured,
LRDI alarms are raised and cleared.
Reports a LOC which causes the
operational state of the port to be
shut down.
3-39

Advertisement

Table of Contents
loading

Table of Contents