3 — Troubleshooting network alarms
11
12
13
3-14
Figure 3-9 Lsp related objects in Alarm Info form
Find the object type that is lowest in the network object hierarchy, as listed in Table
3-1. The lowest level object is a LAG.
View the navigation tree Equipment tab button. It indicates that there are alarms
related to both existing LAGs (Site Id 10.1.200.52 and Site Id 10.1.200.53).
However, there is no LAG alarm in the dynamic alarm list and the LAG State is Up.
Check states of related, supporting objects for the lowest-level object in the alarm.
Underlying port states may propagate alarms higher up the managed object
hierarchy without causing alarms on ports, LAGs, interfaces, protocols, and
sessions.
i
In the navigation tree Equipment view, choose a port under the LAG on Router
53 (Site 10.1.200.53) and choose Properties from the contextual menu. The
LAG member properties form opens.
ii
Click on the Port tab button to view the underlying port state of the LAG
member, as shown in Figure 3-10. The LAG Member 1/1/2 properties form
shows the Underlying Port State: Shut Down.
Alcatel 5620 Service Aware Manager, Release 2.1 R2
May 2005
95-5887-01-00-B